Most Seagate disks have configurable Extended Power Conditions (EPC) settings that include timers for how long the disk needs to stay idle before entering various low-power modes. Disk vendors typically provide their own vendor-specific ways to do persistent configuration of power management settings, so it’s worth trying to use those instead so the desired configuration doesn’t depend on the host system applying it, instead being configured in the drive (but in some cases it might be desirable to have the host configure that!). To prevent parking the heads at all a value greater than 128 may do the job (254 is a common choice, as the highest-power setting available), but it’s possible that some disks won’t behave this way because the ATA specification refers only to spinning down the disk and does not specify anything about parking heads. Typical SAS connectors support up to 4 drives per “lane”, but with an expander up to 255 devices are possible. An eight lane controller can only directly attach to 8 disks, requiring more controllers (consuming additional PCI-E slots) to connect more drives. This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.
Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use
I will optimize settings later for the security/quietness tradeoff however, I’m very pleased with it for now. How can I set this value on the Truenas interface? Keeping it spinning but not accessing data is safer. I would still recommend against idling your drive as that reduces longevity. I also set the tunable vfs.zfs.txg.timeout to a somewhat large value so the regular syncs don’t happen every 5 seconds.

Smart Check Intervals & HDD Head Parking

I noticed that even when doing nothing, I hear the sound of drives working every few seconds. I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent. I guess it depends on the drives, but don’t think you’ll find any software solution. My Seagate Exos enterprise drives make almost 0 noise actually. The system is never idle really, it’s a server. What causes the constant load on the disk?

  • I agree to receive your newsletters and accept the data privacy statement.
  • This example creates a new GPT partition scheme on da36, creates a 4 GiB swap partition aligned to 1 MiB boundaries, and then adds a ZFS partition with the label e3s01-ZGY0XH87 using the remainder of the space on the disk.
  • I’m looking for a software solution, if possible, to make the HDD idling for most of the time when there is no load.
  • FreeBSD’s sesutil is a tool to interface with the SES devices on your system.
  • The smartmon_load_cycle_count_value metric seems like it would be the right one to query, but that actually expresses a percentage value (0-100) representing how many load cycles remain in the specified lifetime- on reaching 0 the disk has done a very large number of load cycles.

For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.

How do I connect to an unattended desktop with AnyDesk?

Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.

Storage Media Options

In this case, there are at least two disks that I probably need to configure, since /dev/sde seems to be parking as often as about every 4 minutes (0.004 Hz) and /dev/sdc is only parking slightly less often. The smartmon_load_cycle_count_value metric seems like it would be the right one to query, but that actually expresses a percentage value (0-100) representing how many load cycles remain in the specified lifetime- on reaching 0 the disk has done a very large number of load cycles. It does support reading arbitrary metrics from text files written by other programs with its textfile collector however, which is fairly easy to integrate with arbitrary other tools. These communities are filled with knowledgeable individuals who can offer more personalized advice and help you navigate the complexities of long-term data storage.

�������� ����������� AnyDesk

However, I noticed that my HDD’s heads park (particulary Seagate Exos) every 3 minutes. ZFS is widely trusted for large-scale storage, but production environments expose design mistakes,… When dealing with critical data, you only get one chance to do it right. The status field is a bitmask supporting a number of different options, but the main ones we care about are 1 (OK), and 2 (FAULTED). When combined with a JSON parser like jq, this can be used to automate tasks for each disk.

Preventing excessive parking

The settings you mentioned are already set this way. After you apply these settings the logs will be written to your SSD instead of being flushed to the disc array. Those are probably the system logs being flushed to disk every few seconds. I have moved the system data to my boot SSDs, don’t have any apps installed and don’t have any pool set for apps.

SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph reveryplay of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.
Unfortunately, APM settings don’t persist between power cycles so if we wanted to change disk settings with APM they would need to be reapplied on every boot. Advanced power management levels80h and higher do not permit the device to spin down to save power. For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh. To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports. With the SMART metrics captured by Prometheus, it’s fairly easy to write a query that will show how often a given disk is parking its heads. Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.
If you need more advanced functionality than mpsutil provides, LSI provides their native tools sas2ircu and sas3ircu for FreeBSD. On my system, this command produces a bright red LED lit for that slot, physically highlighting the correct drive to replace. So, to activate the LED for the first disk displayed above, we first need to determine the enclosure handle number (0001), and then the slot number of the disk (03). This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk. As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.

  • It also provides information about each slot in the enclosure (even if empty), including a flag to indicate if the device has recently been swapped.
  • Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.
  • I moved the system dataset to the boot pool.
  • Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s.
  • If you’d feel safer with a team of experts monitoring your storage, consider a ZFS Support Subscription.
  • These practices and tools should give you a solid starting point for recovering your deleted files.

Once you’ve done so, you must test delivery to your “real” inbox—you don’t want to learn that delivery isn’t working after your storage has already become unavailable! If you’d feel safer with a team of experts monitoring your storage, consider a ZFS Support Subscription. If you rely on manually checking on your storage periodically, you will regret it. Another important aspect of managing your storage system is configuring notifications. Klara recommends embedding these details directly into the ZFS vdev properties of each disk—a feature Klara created, which will become generally available in the upcoming OpenZFS 2.2 release. In these configurations, your system may or may not support features like individual “locate” and “fault” LEDs.